- Research
- Open access
- Published:
Condensation methodology for quantification of Polymyxin B fluorimetrically: application to pharmaceutical formulations and greenness assessment
BMC Chemistry volume 18, Article number: 105 (2024)
Abstract
The appearance of multidrug-resistant Gram-negative bacterial infections, along with the lack of newly discovered antibiotics, resulted in the return to old antimicrobial medications like Polymyxins. As a result, the suggested technique aims to develop a fast, environmentally friendly, and sensitive fluorimetric method for quantifying Polymyxin B. The investigated approach depends on generating a highly fluorescent derivative by a condensation pathway between the studied drug and ninhydrin in the presence of phenylacetaldehyde and then estimated spectrofluorimetrically. After the reaction conditions were well optimized, the fluorescent product was estimated at emission wavelength (λem) = 475.5 nm (following excitation at a wavelength (λex) = 386 nm. The developed calibration plot displayed rectilinear throughout the following range (0.2-3 µg mL− 1), and the calculated limit of detection and quantification were 0.062 µg mL− 1 and 0.187 µg mL− 1, respectively. As a consequence, the drug’s ophthalmic and intravenous pharmaceutical forms were both successfully quantified with an excellent degree of recovery. Finally, the methodology’s greenness was assessed utilizing Analytical Eco-Scale scores.
Introduction
The treatment of multidrug-resistant (MDR) bacterial infections remains a major unresolved clinical demand despite considerable progress across the scientific fields. Due to the limited development of new antibiotics capable of treating these types of infections, scientists are returning to older antimicrobial medications [1]. Polymyxins (PMS), notably Polymyxin B (Poly B), have attracted attention due to their specific efficacy against MDR Gram-negative bacteria. Poly B, a cyclic polypeptide protein widely used for clinical purposes, disrupts bacterial cell membranes, causing cell death, as shown in (Fig. 1).
Belongs to published papers, more than one chromatographic approach as HPLC [2,3,4,5,6,7] and LC-Mass [8,9,10,11,12,13,14,15,16,17,18,19] also microbiological articles were reported [20, 21]. On the other hand, spectroscopic techniques were listed, including spectrophotometric [22,23,24,25] and spectrofluorimetric [26,27,28] approaches. Owing to its simplicity, sensitivity, and no need for a complex apparatus or sample preparation, the spectrofluorimetry technique is frequently employed in recent drug analyses. On the other side, separative techniques have several drawbacks such as excessive solvent utilization, equipment with high cost, and exhausted extraction operations. Furthermore, spectrophotometric and microbiological tests lack sensitivity.
The previously reported fluorimetric methods had limitations such as utilizing drastic conditions (boiling for a long time, 35 min.) [28] or employing an expensive reagent [27], or using hazardous chemicals [26]. So the described approach aimed to overcome these drawbacks by establishing a fast, cost-effective, and environmentally friendly methodology to be easily applied in routine quality control assay.
Ninhydrin, in the presence of phenylacetaldehyde, is a commonly used derivatizing reagent for numerous primary amine-containing pharmaceuticals for spectrophotometric and spectrofluorimetric analysis, owing to its accuracy, cost-effectiveness, and reproducibility. In this study, the fluorogenic reagents interacted with Poly B’s primary amine groups to form a highly fluorescent derivative, which was detected at λex = 386 nm and λem = 475.5 nm.
Experimental
Devices
A Jasco FP-8350 spectrofluorimeter (Tokyo, Japan) was employed to obtain the spectrofluorimetric measurements. The apparatus had a 150 W Xenon-arc lamp, a 400 V PMT voltage, a 5 nm slit width for both the emission and excitation monochromators, and a 1000 nm. min− 1 scan rate. Also, a temperature controller (Schwabach, Germany) and pH meter Adwa AD 1100 (Romania) were utilized in the prescribed approach.
Chemicals and reagents
Standard Poly B was kindly gifted from The National Organization of Drug Control and Research (NODCAR), which was used without additional purification. Paximid® vial a product of Cipla Company product (is claimed to contain 500,000 IU, which is equal to 5 mg of the studied drug). Terramycin® ophthalmic ointment, a product from Pfizer pharmaceutical company (contains 10,000 IU of Poly B equivalent to 1.6667 mg per 1 gm). Ninhydrin, 0.1% (w/v) (Alpha Chemicka, Mumbai, India) was daily prepared in distilled water, and phenylacetaldehyde, 0.2% (v/v) (Sigma Aldrich, Germany) was weekly set in ethyl alcohol. All experimental solvents, including acetone, acetonitrile, methyl alcohol, ethyl alcohol, hexane, and dimethylformamide (DMF), were supplied by ElNasr Chemical CO (Cairo, Egypt). The same company also supplied phosphoric acid, citric acid, HCL, and NaOH. Adjust the pH of Teorell & Steinhagen buffer using 0.1 M HCL after mixing suitable quantities of 1 molar sodium hydroxide, citric, and phosphoric acids.
Standard drug solution preparation
The Poly B stock solution at a final concentration of 100 µg mL− 1 was daily prepared by dissolving 10 mg of Poly B in distilled water. After further dilution, working solutions were obtained.
General analytical procedures
Numerous test tubes were pipetted with 1 mL of working solutions in a range of 2 to 30 µg mL− 1 along with 1 mL of Teorell& Steinhagen buffer (pH = 7), and 1 mL of 0.1% (w/v) ninhydrin, and 0.02% (v/v) phenylacetaldehyde solutions. To ensure a reaction pathway was completed, all tubes were kept in a water bath of 80 °C for 15 min, after which it was cooled in an ice bath. The mixtures in the test tubes were transferred to 10.0-mL volumetric flasks and completed to mark using ethyl alcohol. Lastly, relative fluorescence intensity (RFI) was evaluated at λem = 475.5 nm (after λex = 386 nm). With each experiment, a blank was employed, following all previous procedures but without the addition of the studied drug.
Preparation of vial solution
An accurate amount from Paximid® vials equal to 10 mg of Poly B was transferred to a 100-mL volumetric flask and completed to mark with the employed solvent. Sequential dilution was carried out until the concentration reached (2–30 µg mL− 1), after which all steps in Sect. 2.4 were repeated.
Preparation of ophthalmic ointment solution
An exact quantity of Terramycin® eye ointment equivalent to 10 mg of Poly B was vigorously shaken with 30 mL of a mixture solution of distilled water and n-hexane in a ratio of 1:1. Using a separating funnel, the two immiscible layers were obtained, after which the aqueous layer was collected and the organic one received further aqueous washings. Then the collecting solution was transferred to a 100-mL volumetric flask and completed to mark by distilled water. After filtering, further dilution was employed to obtain working solutions, and general analytical procedures were followed.
Results and discussion
In the presence of phenylacetaldehyde, ninhydrin is utilized as a derivatizing agent to assay drugs with primary amine groups. producing yellow fluorescent derivatives [29,30,31,32,33,34,35,36]. In the developed experiment, ninhydrin condensed with the amino moiety of Poly B in addition to phenylacetaldehyde at λem = 475.5 nm (following excitation at λex. = 386 nm). The reaction pathway and the spectra are illustrated in (Fig. 2) and (Fig. 3), respectively. To raise the value of the current work, a comparative table with other reported fluorimetric articles was established, and all values were inserted in (Table 1).
Optimization of the reaction parameters
To determine the ideal reaction conditions that would yield the highest RFI values, each parameter was optimized while the others remained fixed.
Buffer optimization
Since any small change in the pH of the experimental media had a considerable influence on the approach’s fluorescence intensity, Teorell & Steinhagen buffer was employed to establish a pH scale (5–9). The RFI peaked at a pH range (6.8–7.2); any deviation led to a significant decrease in fluorescence intensity. While checking the optimal buffer volume, the (0.8–1.2 mL) range yielded the best outcomes. So, one mL of the utilized buffer (pH 7) was the best choice. Data are shown in (Fig. 4).
Regeants volume optimization
To study the optimum volumes of ninhydrin and phenylacetaldehyde affect the approach performance, a scale of (0.5–2.0 mL) was successfully investigated. RFI was raised in tandem with increased volumes of each of them until a plateau was reached at 0.8 to 1.2 mL, beyond this range, fluorescence declined. Therefore, 1.0 mL was the optimum volume from each reagent. All information was gathered in (Fig. 5).
Temperature and heating time optimization
A temperature controller instrument was employed to get various degrees of temperatures in the range of 50 to 100 °C. RFI peaked at 60 to 90 °C. After which, various heating time was tested at 80 °C. Fluorescence increased rapidly as the time intervals were extended until reached a steady line at 10 to 20 min. As a result, heating at 80 °C for 15 min. was the optimum thermal setting. All data were gathered in (Fig. 6) and (Fig. 7).
Solvent optimization
While other variables were kept constant, acetone, acetonitrile, ethyl alcohol, methyl alcohol, distilled water, and DMF were employed to further dilute the final fluorescent products. Ethyl and methyl alcohols have the greatest RFI levels, consequently, ethyl alcohol was chosen as the optimum one owing to its greenness profile, as displayed in (Fig. 8).
Validation of the studied method
The proposed approach was carefully validated using ICH criteria [37], which included estimating its linearity and range, accuracy, precision, robustness, and sensitivity, as well as LOD and LOQ.
Linearity & range
A calibration curve of the developed method was plotted of Poly B different concentrations versus RFI values. A linear relationship in the range of 0.2 to 3 µg mL− 1 was obtained, with a correlation coefficient value of 0.9996. All analytical parameters related to the linear regression equation were inserted in (Table 2).
Accuracy
Over the methodology’s calibration range, five different concentrations of the studied drug of 0.2, 0.6, 1, 2, or 3 µg mL− 1 were evaluated three times. The calculated data showed a significant agreement between the experimental and true values, proving the current technique was accurate. All values were inserted in (Table 3).
Precision
Three different drug concentration levels (0.6, 1.5, and 3 µg mL− 1) and three duplicates of each one were utilized throughout the day and over three successive days to assess intra- and inter-day precision, respectively. The calculated mean relative standard deviation (RSD), did not surpass 2, indicating that the proposed methodology was reliable and reproducible. (Table 4) gathering all information.
Robustness
The method’s robustness was estimated by checking small changes in approach conditions like pH and fluorogenic reagent volumes. The tested parameter was altered while the others remained constant, then the recovery percentage (%R) was estimated. Minor alterations had no significant influence on the approach’s performance since the obtained RSD did not exceed 2%, so the outcomes confirmed the robustness of the described approach. All values were inserted in (Table 5).
To assess the sensitivity of the technique under investigation, LOD, and LOQ values were computed. Using the equation “LOD = 3.3 × ϭ / S or LOQ = 10 × ϭ / S,” where S denotes the calibration graph’s slope and ϭ denotes the intercept’s standard deviation, LOD = 0.187 µg mL− 1 and LOQ = 0.062 µg mL− 1 were accurately estimated.
Application of the developed method
The suggested methodology was successfully employed to determine the amount of Poly B in the paximid® vial and Terramycin® eye ointment. %R values of the established approach were statistically compared with a previously published article [28], which showed lower T and F values than tabulated ones, showing good accuracy and precision of the developed methodology. All data were observed in (Table 6).
Greenness evaluation
Various metrics have been used to assess the analytical method’s greenness, such as Analytical Eco-Scale (AES) [38]. The formula used to compute the AES score is 100 minus the total penalty point, considering parameters such as reagent amounts, occupational risks, waste, and energy. The higher the score reflects the more green the methodology. The designed approach included no extraction step, and the operation consumed less than 0.1 kW/h of energy for one sample. With an Eco-Scale score of 90, the developed approach can be regarded as having outstanding greenness. A comparison between the developed and reported approaches is illustrated in (Table 7).
Conclusion
Through utilizing the amino group present in Poly B, designing a new and rapid fluorimetric strategy for quantification of the cited drug in intravenous and ophthalmic dosage forms was the aim of the current work. The extraction step, as well as the employment of instruments with a high cost, solvents, and reagents with a high grade of purity, were all obstacles that were overcome in the current approach. Lastly, AES tool was employed to assess the approach’s greenness. As a consequence, the current methodology could successfully quantify the studied drug in quality control laboratories with a high degree of reproducibility and greenness.
Data availability
The datasets during and/or analyzed during the current study are available from the corresponding author upon reasonable request.
References
DL P. Multidrug-resistant gram-negative pathogens: the Urgent need for old polymyxins. Adv Exp Med Biol. 2019;1145:9–13. https://doiorg.publicaciones.saludcastillayleon.es/10.1007/978-3-030-16373-0_2
Ghanem A, Marzouk AA, El-Adl SM, Fouad A. A polymer-based monolithic Capillary Column with Polymyxin-B Chiral Selector for the Enantioselective Nano-High Performance Liquid Chromatographic Pharmaceutical Analysis. J Chromatogr A. 2022;1662:462714. https://doiorg.publicaciones.saludcastillayleon.es/10.1016/J.CHROMA.2021.462714
Setiawati H, Harmita H, Suryadi H. Development and validation method for simultaneous quantification of neomycin and polymyxin B by HPLC-ELSD and comparison with microbiological method. J Appl Pharm Sci. 2020. https://doiorg.publicaciones.saludcastillayleon.es/10.7324/JAPS.2020.104016
Cao G, Ali FEA, Chiu F, Zavascki AP, Nation RL, Li J. Development and validation of a reversed-phase high-performance liquid chromatography assay for polymyxin B in human plasma. J Antimicrob Chemother. 2008. https://doiorg.publicaciones.saludcastillayleon.es/10.1093/jac/dkn343
Pendela M, Adams E, Hoogmartens J. Development of a liquid chromatographic method for ear drops containing neomycin sulphate, polymyxin B sulphate and dexamethasone sodium phosphate. J Pharm Biomed Anal. 2004. https://doiorg.publicaciones.saludcastillayleon.es/10.1016/j.jpba.2004.08.011
Orwa JA, Van Gerven A, Roets E, Hoogmartens J. Liquid chromatography of polymyxin B sulphate. J Chromatogr A. 2000. https://doiorg.publicaciones.saludcastillayleon.es/10.1016/S0021-9673(99)00936-X
Chaudhary T, Das Kurmi B, Singh D. Convenient estimation of oxytetracycline and polymyxin B by a novel high-performance liquid chromatography method: development and validation, (2023) 6–17.
Wang P, Zhang Q, Qin Z, Xing H, Xu M, Pei H, Yang J, Zhang X. A simple and robust liquid chromatography with Tandem Mass Spectrometry Analytical Method for Therapeutic Drug Monitoring of plasma and cerebrospinal fluid polymyxin B1 and B2. Ther Drug Monit. 2020. https://doiorg.publicaciones.saludcastillayleon.es/10.1097/FTD.0000000000000754
Liu X, Yu Z, Wang Y, Wu H, Bian X, Li X, Fan Y, Guo B, Zhang J. Therapeutic drug monitoring of polymyxin B by LC-MS/MS in plasma and urine, Bioanalysis. (2020). https://doiorg.publicaciones.saludcastillayleon.es/10.4155/bio-2020-0051
Zhang B, Li X, Chen Y, Chen B, Cheng Y, Lin H, Que W, Liu M, Zhou L, Zhang H, Qiu H, Wu C. Journal of Pharmaceutical and Biomedical Analysis determination of polymyxin B in human plasma and epithelial lining fluid using LC-MS / MS and its clinical application in therapeutic drug monitoring. J Pharm Biomed Anal. 2023;227:115291. https://doiorg.publicaciones.saludcastillayleon.es/10.1016/j.jpba.2023.115291
Wang Y, Chen J, Du J, Lei L, Zhao B, Bai Y, Chen D, Wang X, Chen C. The Determination of Polymyxin B in Critically Ill Patients by the HPLC-MS / MS Method, 2023 (2023).
Covellia J, Ruszaj D, Straubinger R, Li J, Rao G. The development and validation of a simple liquid chromatography-tandem mass spectrometry method for polymyxin B1 and B2 quantification in different matrices. J Chromatogr B Analyt Technol Biomed Life Sci. 2017;1065–6. https://doiorg.publicaciones.saludcastillayleon.es/10.1016/J.JCHROMB.2017.09.031
Cheng C, Liu S, Xiao D, Hollembaek J, Yao L, Lin J, Hansel S. LC-MS/MS method development and validation for the determination of polymyxins and Vancomycin in rat plasma. J Chromatogr B Anal Technol Biomed Life Sci. 2010;878:2831–8. https://doiorg.publicaciones.saludcastillayleon.es/10.1016/j.jchromb.2010.08.037
Hee KH, Leaw YKJ, Ong JL, Lee LS. Development and validation of liquid chromatography tandem mass spectrometry method quantitative determination of polymyxin B1, polymyxin B2, polymyxin B3 and isoleucine-polymyxin B1 in human plasma and its application in clinical studies. J Pharm Biomed Anal. 2017;140:91–7. https://doiorg.publicaciones.saludcastillayleon.es/10.1016/j.jpba.2017.03.018
Cheah SE, Bulitta JB, Li J, Nation RL. Development and validation of a liquid chromatography-mass spectrometry assay for polymyxin B in bacterial growth media. J Pharm Biomed Anal. 2014;92:177–82. https://doiorg.publicaciones.saludcastillayleon.es/10.1016/j.jpba.2014.01.015
Huang X, Liu X, Wang Y, Zhang J. Determination of polymyxin B in dried blood spots using LC-MS/MS for therapeutic drug monitoring. J Chromatogr B Anal Technol Biomed Life Sci. 2022;1192:123131. https://doiorg.publicaciones.saludcastillayleon.es/10.1016/j.jchromb.2022.123131
Meng M, Wang L, Liu S, Jaber OM, Gao L, Chevrette L, Reuschel S. Simultaneous quantitation of polymyxin B1, polymyxin B2 and polymyxin B1-1 in human plasma and treated human urine using solid phase extraction and liquid chromatography-tandem mass spectrometry. J Chromatogr B Anal Technol Biomed Life Sci. 2016;1012–3. https://doiorg.publicaciones.saludcastillayleon.es/10.1016/j.jchromb.2016.01.013
Zhang H, Li F, Dun J, Sun N, Liu H, Chen G. Combination of Derivatization–HPLC–MS and enzymatic hydrolysis–edman degradation for amino acid sequence and configuration of Polymyxin B Components. Chromatographia. 2021;84:1057–64. https://doiorg.publicaciones.saludcastillayleon.es/10.1007/s10337-021-04091-2
Thomas TA, Broun EC, Abildskov KM, Kubin CJ, Horan J, Yin MT, Cremers S. High performance liquid chromatographyg-mass spectrometry assay for polymyxin B1 and B2 in human plasma. Ther Drug Monit. 2012. https://doiorg.publicaciones.saludcastillayleon.es/10.1097/FTD.0b013e31825c827a
Liu J, Huang Z, Ruan B, Wang H, Chen M, Rehman S, Wu P. Quantitative proteomic analysis reveals the mechanisms of polymyxin B toxicity to Escherichia coli. Chemosphere. 2020. https://doiorg.publicaciones.saludcastillayleon.es/10.1016/j.chemosphere.2020.127449
Kjeldsen NJ, Beezer AE, Miles RJ. Flow microcalorimetric assay of antibiotics-III. Zinc bacitracin and its combinations with polymyxin B sulphate and neomycin sulphate on interaction with Micrococcus luteus. J Pharm Biomed Anal. 1989;7:865–9. https://doiorg.publicaciones.saludcastillayleon.es/10.1016/0731-7085(89)80007-X
Mannan A, Khan AJ, Khan M, Abbas G. Validated Spectrophotometric Method for determination of Polymaxin-B sulfate in Pharmaceutical formulations. RADS J Pharm Pharm Sci. 2017;5:33–8. http://www.jpps.juw.edu.pk/index.php/jpps/article/view/176. (accessed December 26, 2020).
Severino P., Silveira E.F., Vazzana M, Chaud MV, Santana M.H.A., Souto E.B. Validation of an UV spectrophotometric assay for the quantification of polymyxin B in solid lipid nanoparticles. Pharmazie. 2015. https://doiorg.publicaciones.saludcastillayleon.es/10.1691/ph.2015.5073
Lemus Gallego JM, Pérez J, Arroyo. Spectrophotometric resolution of ternary mixtures of Dexamethasone, Polymyxin B and Trimethoprim in synthetic and pharmaceutical formulations. Anal Chim Acta. 2001;437:247–57. https://doiorg.publicaciones.saludcastillayleon.es/10.1016/S0003-2670(01)01008-X
Gallego JML, Arroyo JP. Simultaneous resolution of dexamethasone and polymyxin B by spectrophotometry derivative and multivariate methods. Anal Lett. 2001;34:1265–83. https://doiorg.publicaciones.saludcastillayleon.es/10.1081/AL-100104152
El-Kosasy AM, Abdel-Aziz O, Magdy N, El NM, Zahar. Screening and optimization of the reaction of polymyxin B sulphate with NBD-Cl for the synchronous spectrofluorimetric determination of polymyxin B sulphate in human plasma. J Fluoresc. 2015. https://doiorg.publicaciones.saludcastillayleon.es/10.1007/s10895-015-1555-8
Badr El-Din KM, Abdelmajed MA, Omar MA, Attia TZ. Salvage parenteral antibiotics for multidrug-resistant (MDR) Gram-negative bacteria; a fluorescamine-based technique for ultrasensitive spectrofluorimetric measurement of polymyxins; human plasma application. Luminescence. 2022;37:971–9. https://doiorg.publicaciones.saludcastillayleon.es/10.1002/bio.4245
Attia TZ, Abdelmajed MA, Omar MA, El-Din KMB. Selective Spectrofluorimetric Protocol for determination of commonly used Gram-negative Bactericidal Drug in Combined Pharmaceutical Dosage forms and Human plasma. J Fluoresc. 2022;32:603–12. https://doiorg.publicaciones.saludcastillayleon.es/10.1007/s10895-021-02862-6
Ali MFB, Salman BI, Hussein SA, Marzouq MA. Applicability of ninhydrin as a fluorescent reagent for estimation of teicoplanin in human plasma using salting-out assisted liquid-liquid extraction technique. Luminescence. 2020;35:1118–24. https://doiorg.publicaciones.saludcastillayleon.es/10.1002/BIO.3824
Abdel-Lateef MA, Almahri A. Spectrofluorimetric determination of α-difluoromethylornithine through condensation with ninhydrin and phenylacetaldehyde: application to pharmaceutical cream and spiked urine samples. Chem Pap. 2022;76:741–8. https://doiorg.publicaciones.saludcastillayleon.es/10.1007/S11696-021-01894-3/TABLES/3
Anwer EF, Nour El-Deen DAM, Omar MA. Design and strategy for spectrofluorimetric determination of tranexamic acid in its authentic form and pharmaceutical preparations: application to spiked human plasma. Luminescence. 2021;36:1327–34. https://doiorg.publicaciones.saludcastillayleon.es/10.1002/BIO.4068
Omar MA, Nagy DM, Halim ME. Utility of ninhydrin reagent for spectrofluorimetric determination of heptaminol in human plasma. Luminescence. 2018;33:1107–12. https://doiorg.publicaciones.saludcastillayleon.es/10.1002/BIO.3516
Derayea SM, Attia TZ, Elnady M. Development of spectrofluorimetric method for determination of certain antiepileptic drugs through condensation with ninhydrin and phenyl acetaldehyde, Spectrochim. Acta - Part A Mol. Biomol Spectrosc. 2018;204:48–54. https://doiorg.publicaciones.saludcastillayleon.es/10.1016/j.saa.2018.06.027
Mostafa IM, Derayea SM, Nagy DM, Omar MA. An experimental ninhydrin design approach for the sensitive spectrofluorimetric assay of milnacipran in human urine and plasma. Spectrochim Acta - Part Mol Biomol Spectrosc. 2018;205:292–7. https://doiorg.publicaciones.saludcastillayleon.es/10.1016/j.saa.2018.07.040
Omar MA, Derayea SM, Mostafa IM. Selectivity improvement for Spectrofluorimetric Determination of Oseltamivir Phosphate in human plasma and in the Presence of its degradation product. J Fluoresc. 2017;27:1323–30. https://doiorg.publicaciones.saludcastillayleon.es/10.1007/s10895-017-2066-6
Attia TZ, Abdelmajed MA, Omar MA, Al Thagfan SS, El-Din KMB. New validated spectrofluorimetric protocol for colistin assay through condensation with 2, 2-dihydroxyindan-1, 3-dione: application to content uniformity testing. RSC Adv. 2022;12:33559–66.
I.C.H.H T, Guideline, editors. others, Validation of analytical procedures: text and methodology, Q2. 1 (2005) 5.
Gałuszka A, Migaszewski ZM, Konieczka P, Namieśnik J. Analytical Eco-scale for assessing the greenness of analytical procedures. TrAC - Trends Anal Chem. 2012;37:61–72. https://doiorg.publicaciones.saludcastillayleon.es/10.1016/j.trac.2012.03.013
Funding
Non-funding.
Author information
Authors and Affiliations
Contributions
Mahmoud A. Abdelmajed: Methodology and writing the original draft, Tamer Z. Attia: Validation and reviewing, Khalid M. Badr El-Din: reviewing and publishing editing, Mahmoud A. Omar and Mohamed Orab: reviewing.
Corresponding author
Ethics declarations
Ethical approval and consent to participate
Not applicable.
Consent for publication
Not applicable.
Ethical guidelines
Guidelines according to BMC journal.
Competing interests
The authors declare that they have no competing interests.
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
About this article
Cite this article
Abdelmajed, M.A., El-Din, K.M.B., Attia, T.Z. et al. Condensation methodology for quantification of Polymyxin B fluorimetrically: application to pharmaceutical formulations and greenness assessment. BMC Chemistry 18, 105 (2024). https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s13065-024-01156-9
Received:
Accepted:
Published:
DOI: https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s13065-024-01156-9