Skip to main content

Table 1 Analytical techniques and performance of the developed methods for RIS quantification

From: Use of gold/iron metal-organic framework nanoparticles (AuNPs/FeMOF)-modified glassy carbon electrode as an electrochemical sensor for the quantification of risperidone in patient plasma samples

Technique

Samples

Dynamic range (µg/mL)

LOD/LLOQ (µg/mL)

Ref.

Optical

(Fluorescence)

Human urine

-

0.103

[1]

Optical

(Fluorescence)

Pharmaceutical, human plasma

5–150 ng/mL

1.37 ng/mL

[19]

HPLC-UV

pharmaceutical preparations

10–60

1.79

[44]

UPLC-MS/MS

spiked human serum

0.200–500 ng/mL

LLOQ = 0.2 ng/mL

[45]

Electrochemical

(AdSDPV )

Pharmaceutical, spiked human serum

0.04–0.82

0.04

[4]

Electrochemical

(SWV)

pharmaceutical preparations

0.02–32.1

0.02

[8]

Electrochemical

(SWVs )

Human plasma

0.02-50

LLOQ = 0.02

This work