Skip to main content

Table 1 Validation data of VER by the proposed methods

From: Utility of green chemistry for spectrofluorometric and spectrophotometric analysis of vericiguat via reaction with erythrocin B

Parameter

Spectrofluorometric method

Spectrophotometric method

Concentration range (µg mL− 1)

0.05–0.5

0.5–10.0

Detection limit (µg mL− 1)

0.012

0.131

Quantitation limit (µg mL− 1)

0.036

0.412

Determination coefficient (r2)

0.9996

0.9999

Slope

1131

0.0578

Intercept

47.83

0.0729

Sy/x

1.8358

0.0061

Sa

12.467

0.0075

Sb

17.796

0.0083

% Error

0.764

0.675

% RSD

1.964

1.432

Mean found (%) ± SD

100.76 ± 0.987

99.89 ± 1.01

  1. Note: Sa, standard deviation of the intercept of regression line; Sb, standard deviation of the slope of regression line; Sy/x, standard deviation of the residuals