Skip to main content

Table 2 Regression and validation data for the determination of pantoprazole and domperidone by the proposed methods

From: A green three-ratio manipulating spectrophotometric approaches for the determination of a binary mixture of pantoprazole and domperidone

Parameters

RD

1DD

MC

PNT

DOM

PNT

DOM

PNT

DOM

Wavelength (nm)

254–223

208–232

249

215

254

209

Linearity range (μg/mL)

0.5–52

1–18

0.5–52

1–18

0.5–52

1–18

LOD (μg/mL)

0.209

0.621

0.209

0.625

0.209

0.624

LOQ (μg/mL)

0.442

0.912

0.443

0.913

0.439

0.916

 Slope (b)

1.0104

0.1706

0.9694

0.0116

1.4331

0.2694

 Intercept (a)

− 0.2941

− 0.0032

0.2557

0.0007

− 0.4035

− 0.2742

Coefficient of determination (r2)

0.9998

0.9998

0.9999

0.9998

0.9999

0.9999

Accuracy (%R)a

100.39

100.17

99.72

99.96

100.23

99.35

Repeatability precision (RSD)b

1.176

1.141

0.976

0.959

1.509

1.178

Intermediate precision (RSD)b

1.001

0.919

0.965

0.847

0.79

1.133

Robustnessc (%RSD)

Wavelength (± 1 nm)c

1.251

1.181

1.061

0.972

1.372

1.206

  1. aNine measurements were averaged (three times in three different concentrations)
  2. b%RSD of nine measurements (three times in three different concentrations)
  3. c%RSD of determination of three concentrations of each drug after slight changes in the wavelength (± 1 nm)