Skip to main content

Table 2 Application of the proposed method for determining PDN and DXZ in their raw materials

From: Sensitive and selective silver nanoparticle-based fluorescence sensor for corticosteroid determination in pharmaceutical formulations

Parameter

PDN

DXZ

Conc. taken (µg/mL)

% Found a

Comparison method [21]

Conc. taken (µg/mL)

% Found a

Comparison method [23]

% Found a

% Found a

 

1.0

101.30

100.70

1.0

100.20

101.18

 

2.0

99.90

99.65

2.0

98.35

98.72

 

4.0

100.15

100.12

4.0

101.15

100.21

 

5.0

99.74

 

6.0

100.82

 
 

6.0

98.85

 

8.0

98.88

 
 

8.0

100.13

 

10.0

100.30

 
 

10.0

100.42

    

Mean

 

100.07

100.15

 

99.95

100.04

SD

 

0.74

0.53

 

1.10

1.24

t-test

 

0.18 (2.30) *

  

0.11(2.36) *

F-test

 

1.97(19.32) *

  

1.26(5.79) *

  1. a Each result is the average of three separate determinations