Skip to main content

Table 3 Results obtained by applying the proposed HPLC–DAD method for the determination of Telmisartan, Chlorthalidone and Amlodipine in Telma-ACT® Tablets and application of standard addition technique

From: A sustainable HPLC method coupled with diode array detection for versatile quantification of telmisartan, chlorthalidone and amlodipine in a fixed-dose antihypertensive formulation and dissolution studies

Pharmaceutical formulation

HPLC–DAD method

Drug

%Found

 ± SDa

Standard addition technique

Claimed

(μg/mL)

Pure added

(μg/mL)

%Recovery of the pure added amountb

Telma-ACT® Tablets

(Each tablet was Labelled to Contain 40 mg TEL, 12.5 mg CHT & 5 mg AML)

(BN: 30TTM008)

TEL

101.46

 ± 1.30

40

20.0

99.05

40.0

101.75

80.0

100.71

Mean ± SD

100.50 ± 1.36

CHT

98.77

 ± 0.77

12.5

6.25

98.40

12.5

99.20

25.0

100.12

Mean ± SD

99.24 ± 0.86

AML

101.35

 ± 1.33

5

2.5

100.40

5.0

98.00

10.0

99.80

Mean ± SD

99.40 ± 1.25

  1. aAverage of five determinations
  2. bAverage of three experiments