Skip to main content

Table 1 Analytical performance data for the determination of the studied drugs by the proposed spectrophotometric and HPTLC-densitometric methods

From: Independent concentration extraction as a novel green approach resolving overlapped UV–Vis binary spectra and HPTLC-densitometric methods for concurrent determination of levocloperastine and chlorpheniramine

Parameters

ICE

Z°E/US

TLC-densitometric

CPM

LCF

CPM

LCF

Linearity range

3.0–30.0 μg mL−1

3.0–30.0 μg mL−1

0.3–4.0 μg/spot

0.8–10.0 μg/spot

Regression equation

 Slope ± SD

1.2393 ± 0.00003

0.0397 ± 0.00019

3604.31 ± 13.95

3078.49 ± 20.19

 Intercept ± confidence interval*

0.0017 ± 0.0006

0.0076 ± 0.003

743.28 ± 26.334

122.46 ± 19.293

 Correlation Coefficient (r)

0.999

0.999

0.999

0.999

 LOD

0.13 μg mL−1

0.66 μg mL−1

0.03

0.13

 LOQ

0.40 μg mL−1

2.00 μg mL−1

0.09 μg/spot

0.40 μg/spot

  1. * \(\overline{x}\pm t\frac{s}{\sqrt{n} }\) where \(\overline{x }\) is the mean value, and s is the standard deviation at n = 8 and the statistic value of t is 2.365 at 95% confidence interval with 7 degrees of freedom